How it works
Cooling systems normally push their heat into the air around them. Temperate gives them a second route: straight out to space.
A gap in the sky.
The atmosphere absorbs most infrared radiation, but not all of it. Between roughly 8 and 13 micrometres (µm), it is largely transparent. Heat radiated at those wavelengths passes through the atmosphere and leaves the planet.
Our panels are engineered to release as much of their heat as possible within that band.

From your cooling system to space.
- 1
Capture
A heat jacket clamps around the refrigerant pipework of an existing cooling system and draws off extra heat. Nothing is cut into, and the refrigerant stays where it is.
- 2
Carry
A separate water-glycol loop carries that heat to a panel array on the roof or in nearby open space.
- 3
Radiate
The panels spread the heat across their surface and radiate it through the atmospheric window. It leaves the planet rather than warming the air around the site.
- 4
Benefit
The refrigerant reaches the next stage of the cycle colder than before. The system keeps its capacity above its design limit, and its compressor does less work.
Why CO₂ systems feel it most.
Much of UK and European refrigeration has moved to CO₂, which is far better for the climate but loses efficiency quickly as outdoor temperatures rise. Subcooling the refrigerant is an established way to win that efficiency back. Our panels do it without an expensive plant upgrade.
Built for the hottest days.
*Stronger when it matters.
Conventional condensers lose capacity as the air around them heats up. Our panels reject their heat mainly by radiation into outer space, which depends far less on air temperature, so they keep working when the condenser struggles.
*Closed water loop.
No supply challenges, no treatment equipment, no damage to coils, and no Legionella risk.
*Sends heat off the planet.
Conventional heat rejection warms the air around the building. Our panels send heat through the atmosphere to outer space. No heat island effect.
*Low disruption.
Installation downtime takes a couple of hours and can be done outside of trading time. Everything else is installed while the site keeps running.
*Fully reversible.
The system can be turned off with the flick of a switch, and the existing cooling system carries on exactly as before.
Is your site suitable?
- *Roof or ground space near the cooling plant to host a panel array.
- *A reasonably clear view of the sky.
- *External access to the refrigerant pipe leaving the condenser or gas cooler.
If you're not sure, we can tell you from a short conversation and a site visit.
Get in touch