Applications

    Temperate works with any vapour compression cooling system that has a concentrated source of heat. We're starting with supermarket and cold chain refrigeration.

    Example deployment: a supermarket

    Heat to spacePanel arrayWater-glycol loopCondenser or gas coolerHeat jacketRefrigerant lineCabinets
    Refrigerant lineWater-glycol loop, warmWater-glycol loop, cooled

    The store

    A typical supermarket with a rooftop condenser serving its chilled and frozen cabinets. The refrigeration plant was designed for summer temperatures well below those of recent heatwaves.

    The problem

    On the hottest days, the condenser can't reject enough heat. Staff switch off cabinets to protect the rest, move stock, and lose sales. Every store in the region is doing the same thing at the same time.

    The installation

    1. 1

      Survey

      We check the plant, the pipework, and the space available for panels.

    2. 2

      Overnight connection

      While the store is closed, we fit the heat jacket to the refrigerant line between the condenser and the cabinets. The plant is paused for an hour or two.

    3. 3

      Panels and loop

      We install the panel array and water-glycol loop on the roof while the refrigeration keeps running.

    What it means for your estate.

    • Headroom in a heatwave.

      The refrigerant reaches your cabinets colder, so the plant holds its capacity above its design limit. On the hottest days, the cabinets stay on.

    • Lower electricity use, most of all at peak.

      The compressor does less work all year round, and most of all on the hottest afternoons, when power is most expensive. We measure the saving on site, against your store's own baseline.

    • Keep the plant you have.

      Equipment that still works shouldn't be replaced because the weather moved. Subcooling the refrigerant line reduces the number of duty cycles needed to operate at capacity, extending the life of your plant through reduced wear.

    • Fast, reversible install.

      We connect to the refrigerant line overnight, with the plant paused for an hour or two. Everything else goes in while the store trades. Staff can decouple the system with standard procedures, and the refrigeration carries on as normal.

    Where we go next.

    The same approach works wherever cooling equipment has to reject concentrated heat.

    Buildings

    Air conditioning and chillers serving offices, hospitals and public buildings.

    Industrial processes

    Vapour compression systems that keep manufacturing and its workers safe while maintaining the correct production temperatures.

    Data centres

    Cooling that has to maintain precise server and chip temperatures whatever the weather.

    Running refrigeration that struggles in the heat?

    Tell us about your site and we'll tell you whether we can help.

    Get in touch